<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-21 08-26-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 57 dBuV YLEX
Pilot RDS Phase Difference
7.3 kHz 2.4 kHz 53 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 63 kHz 18999 0,4474
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,2 dBr 3,22 dBr 5,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 8:26, 21.06.2025
RT
"YleX Aamu: Mika Parikka "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 63 kHz MIN: 11 kHz % above 76 kHz: 0,4474 Acquired: 2025/06/21 8.25.43 Total samples: 18999 Equivalent time: 0:15:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,1 dBr MIN: 0,2 dBr AVE: 3,22 dBr % above 12,2 dBr: 0,0 Last value: 1,4 dBr (2025/06/21 8.25.43) 08.12 08.14 08.16 08.18 08.20 08.22 08.24 0 2 4 6 Pm [dBr]